Article intro - Micro- and nanorobots

Science Robotics (vol 9(87),2024) published these great articles on medical microrobots:

1) "Tracking and navigation of a microswarm under laser speckle contrast imaging for targeted delivery" from Qinglong Wang, Qianqian Wang, Zhipeng Ning, Kai Fung Chan 

Abstract

Micro- and nanorobots have been widely proposed for various medical applications, including drug delivery and thrombolysis. However, tracking these swarms of robots in real time has been challenging, especially for imaging modalities that rely on extended exposure to ionizing radiation. Wang et al. report on the use of laser speckle contrast imaging to track a swarm of magnetic nanorobots within blood vessels in real time and guide their endovascular navigation. The authors demonstrated the potential for high contrast imaging and navigation of the swarm of nanorobots in stagnant and flowing blood environments ex vivo and in vivo. The findings offer an opportunity for improvements in targeted endovascular delivery. 

2) "Human-scale navigation of magnetic microrobots in hepatic arteries" by Ning Li, Phillip Fei , Cyril Tous, Mahdi Rezaei Adariani, Marie-Lou Hautot, Inès Ouedraogo, Amina Hadjadj, Ivan P. Dimov, Quan Zhang, ..., and Gilles Soulez

Abstract

"Using external actuation sources to navigate untethered drug-eluting microrobots in the bloodstream offers great promise in improving the selectivity of drug delivery, especially in oncology, but the current field forces are difficult to maintain with enough strength inside the human body (>70-centimeter-diameter range) to achieve this operation. Here, we present an algorithm to predict the optimal patient position with respect to gravity during endovascular microrobot navigation. Magnetic resonance navigation, using magnetic field gradients in clinical magnetic resonance imaging (MRI), is combined with the algorithm to improve the targeting efficiency of magnetic microrobots (MMRs). Using a dedicated microparticle injector, a high-precision MRI-compatible balloon inflation system, and a clinical MRI, MMRs were successfully steered into targeted lobes via the hepatic arteries of living pigs. The distribution ratio of the microrobots (roughly 2000 MMRs per pig) in the right liver lobe increased from 47.7 to 86.4% and increased in the left lobe from 52.2 to 84.1%. After passing through multiple vascular bifurcations, the number of MMRs reaching four different target liver lobes had a 1.7- to 2.6-fold increase in the navigation groups compared with the control group. Performing simulations on 19 patients with hepatocellular carcinoma (HCC) demonstrated that the proposed technique can meet the need for hepatic embolization in patients with HCC. Our technology offers selectable direction for actuator-based navigation of microrobots at the human scale. "

3) "Dexterous helical magnetic robot for improved endovascular access" by R. Dreyfus, Q. Boehler, S. Lyttle, P. Gruber, J. Lussi, C. Chautems, S. Gervasoni, J. Berberat, D. Seibold, [...] , and B. J. Nelson

Abstract

"Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician’s skill and the device’s ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device’s surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig."

Source: Science Robotics




Comments

Popular Posts